Noise Level Equipment Rental

Monitoring & Information System provides rental services with noise meter, meteorological instrument, audio-visual instrument , noise simulation software, and laser Doppler rental services. Users must prepay the rental fee when renting. If the agreed rental period is exceeded, the overdue fee will be calculated when returning.
The following quotations only provide the rental of the main body of the equipment and its kits, excluding personnel attendance and freight, and additional freight is required if delivery is required.
The following quotation includes the basic 2-hour education and training fee, and the education and training locations are all in our company's premises . If you are overtime or need to attend work, the overtime fee and attendance fee will be charged separately.
The rental time is in units of 7 days (weeks). Huaxin Engineering calculates the starting time from the rental time to the return time (the minimum use period is one day ). If there are still remaining days, you can continue to use it next time. For example: pick up the equipment at 10 am on July 24 , return it at 10 am on July 26 , use it for 2 days, and use the remaining 5 days for the next time.
Please call (02) 25781020 or email [email protected]


Environmental Noise Measurement Noise Meter

000
 

Precision Integral Noise Meter

Noise data post-processing software

01dB FUSION Type 1 Precision Integrating Noise Meter

Rental of handheld noise meter and windproof bulb, suitable for general short-term outdoor environmental noise measurement (no rain).
 

Function:

  • Leq automatic calculation period: 10 seconds, 1 minute, 2 minutes, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 8 hours, 24 hours
  • Leq Manual (user defined) calculation period: 0.5 seconds to 1000 hours
  • SPL(Lp): 0.02 sec to 1 sec in increments of 5mS

Different storage parameters can be set for each configuration, which is suitable for the inspection of environmental protection units. Three steps to select the desired measurement time interval and press the execution record button to start the measurement; the measurement time can be set manually, and the shortest time is from 0.02 seconds to 86400 second, it can automatically repeat the continuous measurement or stop after the measurement time is up, and the measured data can be stored in the memory of the noise meter; therefore, the noise data management function can not only store the configuration, but also store the following measured data Parameters: Excluding recordings, the following full-frequency and low-frequency noise data can be stored up to 10,000 or more:

  • Lp:LXY,X=A、B、C、Z;Y=F、S、I
  • Leq:LXYeq,X=A、B、C、Z;Y=F、S、I Lmax:LXYmax,LXY,X=A、B、C、Z;Y=F、S、I
  • Lmin:LXYmin,LXY,X=A、B、C、Z;Y=F、S、I
  • Lpeak:LXYpeak,LXY,X=A、B、C、Z;Y=F、S、I  Ln:L5、L10、L50、L90、L95 and two user-defined Ln values (n=1~99)

Spectrum analysis: 1/3 spectrum or 1/1 spectrum per second

Event recording: event and event recording is optional, and the recording format can be stored in MP3 format. If a 32G SD card is used, it can record continuously for more than 10 days (including measurement data)

Recording format and sampling frequency:

■ RAW original format : 51.2kHz, 25.6kHz, 12.8kHz, 6.4kHz, 3.2kHz, 1.6kHz

■ MP3 Format:48kHz, 32kHz, 16kHz, 8kHz;Dynamic Range: 27-117 or 47-137 dB

● dBTraitNoise Analysis Software

● Accessories: waterproof instrument case, power supply, 32G SD card, simple operation manual in Chinese


Architectural Acoustics Precision Integral Noise Meter

000
 

Architectural Acoustics Precision Integral Noise Meter

Noise data post-processing software

000
 

Noise data post-processing software

Noise data post-processing software

01dB FUSION Type 1 Precision Integrating Noise Meter

Rental of handheld noise meter and windproof bulb, suitable for general short-term outdoor environmental noise measurement (no rain).
 

Function:

  • Leq automatic calculation period: 10 seconds, 1 minute, 2 minutes, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 8 hours, 24 hours
  • Leq Manual (user defined) calculation period: 0.5 seconds to 1000 hours
  • SPL(Lp): 0.02 sec to 1 sec in increments of 5mS

Different storage parameters can be set for each configuration, which is suitable for the inspection of environmental protection units. Three steps to select the desired measurement time interval and press the execution record button to start the measurement; the measurement time can be set manually, and the shortest time is from 0.02 seconds to 86400 second, it can automatically repeat the continuous measurement or stop after the measurement time is up, and the measured data can be stored in the memory of the noise meter; therefore, the noise data management function can not only store the configuration, but also store the following measured data Parameters: Excluding recordings, the following full-frequency and low-frequency noise data can be stored up to 10,000 or more:

  • Lp:LXY,X=A、B、C、Z;Y=F、S、I
  • Leq:LXYeq,X=A、B、C、Z;Y=F、S、I Lmax:LXYmax,LXY,X=A、B、C、Z;Y=F、S、I
  • Lmin:LXYmin,LXY,X=A、B、C、Z;Y=F、S、I
  • Lpeak:LXYpeak,LXY,X=A、B、C、Z;Y=F、S、I  Ln:L5、L10、L50、L90、L95 and two user-defined Ln values (n=1~99)

Spectrum analysis: 1/3 spectrum or 1/1 spectrum per second

Event recording: event and event recording is optional, and the recording format can be stored in MP3 format. If a 32G SD card is used, it can record continuously for more than 10 days (including measurement data)

Recording format and sampling frequency:

■ RAW original format : 51.2kHz, 25.6kHz, 12.8kHz, 6.4kHz, 3.2kHz, 1.6kHz

■ MP3 Format:48kHz, 32kHz, 16kHz, 8kHz;Dynamic Range: 27-117 or 47-137 dB

● dBTraitNoise Analysis Software

● Accessories: waterproof instrument case, power supply, 32G SD card, dBInside architectural acoustic software, Chinese simple operation manual


Outdoor Environmental Noise Measurement Noise Meter

 

Noise Monitoring Analyzer

DMK01 outdoor microphone

000
 

Noise data post-processing software

01dB CUBE Type 1 Precision Integrating Noise Meter

Outdoor precision integral noise monitor, suitable for medium and long-term outdoor all-weather environmental noise measurement.
 

Function:

  • Leq automatic calculation period: 10 seconds, 1 minute, 2 minutes, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 8 hours, 24 hours
  • Leq Manual (user defined) calculation period: 0.5 seconds to 1000 hours
  • SPL(Lp): 0.02 sec to 1 sec in increments of 5mS

Different storage parameters can be set for each configuration, which is suitable for the inspection of environmental protection units. Three steps to select the desired measurement time interval and press the execution record button to start the measurement; the measurement time can be set manually, and the shortest time is from 0.02 seconds to 86400 second, it can automatically repeat the continuous measurement or stop after the measurement time is up, and the measured data can be stored in the memory of the noise meter; therefore, the noise data management function can not only store the configuration, but also store the following measured data Parameters: Excluding recordings, the following full-frequency and low-frequency noise data can be stored up to 10,000 or more:

  • Lp:LXY,X=A、B、C、Z;Y=F、S、I
  • Leq:LXYeq,X=A、B、C、Z;Y=F、S、I Lmax:LXYmax,LXY,X=A、B、C、Z;Y=F、S、I
  • Lmin:LXYmin,LXY,X=A、B、C、Z;Y=F、S、I
  • Lpeak:LXYpeak,LXY,X=A、B、C、Z;Y=F、S、I  Ln:L5、L10、L50、L90、L95 and two user-defined Ln values (n=1~99)

Spectrum analysis: 1/3 spectrum or 1/1 spectrum per second

Event recording: event and event recording is optional, and the recording format can be stored in MP3 format. If a 32G SD card is used, it can record continuously for more than 10 days (including measurement data)

Recording format and sampling frequency:

■ RAW original format : 51.2kHz, 25.6kHz, 12.8kHz, 6.4kHz, 3.2kHz, 1.6kHz

■ MP3 Format:48kHz, 32kHz, 16kHz, 8kHz;Dynamic Range: 27-117 or 47-137 dB

● dBTraitNoise Analysis Software

● Accessories: waterproof instrument case, power supply, 32G SD card, 10-meter microphone extension cable


01dB CAL31 1kHz 94dB standard sound source calibrator

 

01dB Cal31 is a class 1 acoustic calibrator for calibration and adjustment of any type of sound

 

Noise meter with 1/2" diameter microphone, specification according to IEC 60942:2003 Class 1, approved in France by the National Laboratory (LNE) under number LNE33867-0 and in Germany by Physikalisch- Approved by the Technische Bundesanstalt (PTB), number PTB-1.63-4087636.

Consisting of a robust ergonomic housing, it is easy to use, requiring only one button press to activate the signal.

DUO, FUSION and CUBE products will automatically detect a 93.7 dB signal at 1 kHz and start the calibration procedure.


CadnaA outdoor acoustic noise simulation software

 

Simulated noise types and compliance standards: Industry (ISO 9613-2), Road ( RLS-90) and Railway ( Schall03 1990 , 2014 ) .

 
  • Sound source type: covering points, lines, areas (planes), roads, railways and other sound sources.
  • In each screening calculation, up to 1000 buildings and 1000 screening objects.
  • All important features include computational noise maps , dynamic 3D, PCSP, dynmap , web export, graphic design and multithreading support.
  • Combine with GOOGLE MAP , open map, etc. to set the base map.
  • Based on the technical system parameters of the sound source ( for example: electric power KW, flow m3/h, rotational speed rpm ) , the sound power spectrum is automatically generated.

CadnaB Building Acoustics Noise Simulation Software

 
 

Software for calculating airborne and impact sound transmission between rooms throughout a building, including airborne sound from outside the building. The calculation is based on parts 1 to 3 of the standard series ISO 12354 and will be extended to other standards (e.g. DIN 4109) in the future. State-of-the-art software for predicting the sound insulation of an entire building. CadnaB can be used to predict the acoustic performance between rooms in apartments and office buildings , between classrooms in schools, and between rooms in hotels or hospitals.

  • Walls, doors, windows, and other elements can be modeled in 2D while viewing changes in 3D in real time. Bitmap plans can be imported and used as base layers for drawing objects.
  • Several databases of building element data are provided, up to 13 types of databases, these databases usually contain spectral data in one-third octave bandwidth, octave bandwidth can also be used depending on the data source . Users can customize the data to expand the database.
  • CadnaB offers various import options, such as BASTIAN format. Furthermore, CadnaB can be linked to CadnaA and CadnaR , covering a wide range of applications.
  • Export the full report to MS Word format ( .docx ) . You can also export calculation protocols to MS Excel ( .xlsx )

CadnaR Indoor Acoustic Noise Simulation Software

 
 
  • In the workplace, the sound load in the working environment can be calculated according to the EC Directive (2006/42/EC ) , using the machine manufacturer's parameters and room dimensioning.
  • Formulate the planning and evaluation of noise reduction measures, such as: change the layout, set up sound barriers, add wall or ceiling sound absorption layer , change the emitted noise level or other measures.
  • Evaluate alternative locations in conjunction with plans for offices, call centers, common rooms and areas, etc.
  • selection , including cost-benefit analysis of acoustic ceiling or wall cladding , is performed through the Acoustic Product Information Application Library .
  • by calculating the sound level raster distribution ./li>
  • Complex room geometries can also be modeled (using mirroring or particle models).
  • For the modeling of machine layout and other sound sources, point sound sources, line sound sources, surface sound sources, and box sound sources can be used.
  • Point sources can be directional (using simple or 5 degree steps).
  • Evaluate alternative locations in conjunction with plans for offices, call centers, common rooms and areas, etc.

Outdoor Ultrasonic Weather Meter

 

01dB Cal31 is a class 1 acoustic calibrator for calibration and adjustment of any type of sound

 

Technical Parameters Precipitation Rainfall Cumulative rainfall output since the last automatic or manual reset Resolution and unit 0.01 mm, 0.001 inches Accuracy 5%* Rain duration Calculates every ten second increments as soon as water droplets are detected amount

Output resolution and units 10 s Rain Intensity One minute continuous average of observations collected after every ten seconds Range 0 ... 200 mm/h Wider ranges degrade accuracy)

Output resolution and units 0.1 mm/h, 0.01 inches/hour Cumulative number of concentrated surface areas of hailstones

Output resolution and unit 0.1 sample number/cm2, 0.01 sample number/in2, 1 sample number Hail duration As long as hail is detected, it will immediately calculate the increment every ten seconds

Output resolution and unit 10 seconds Hail intensity The continuous average observation value collected for one minute after every ten seconds Output resolution and unit 1 sample number/cm2 hour, 0.01 sample number/in2 hour, 1 sample number/hour* Due to the changing nature of weather conditions and spatial variations, there may be some deviation in rainfall readings, especially for short-term measurements.

Accuracy specifications do not include possible wind sensing errors.

Wind Speed Range 0 ... 60 m/s Response time 250 ms Accuracy 0 ... 35 m/s ±0.3 m/s or ±3%, whichever is higher 35 m/s ... 60 m/s ±5% Output resolution and unit 0.1 m/s, 0.1km/h, 0.1 mph, 0.1 knots Direction azimuth 0 ... 360° Response time 250 ms

Accuracy ±3° Output resolution and unit 1° Temperature range -52 ... +60 °C (-60 ... +140 °F) Sensor accuracy ±0.3 ° at +20 °C C (±0.5 °F) Accuracy over temperature range (see graph below) Atmospheric pressure range 600 ... 1100 hPa Accuracy at 0 ... +30 °C (+32 ... +86 °F) ±0.5 hPa at -52 ... +60 °C (-60 ... +140 °F) ±1 hPa Output resolution relative to units 0.1 hPa, 10 Pa, 0.0001 bar, 0.1 mmHg, 0.01 inHg Humidity range 0 ... 100 %RH Accuracy ±3 %RH within 0 ... 90 %RH ±5 %RH within 90 ... 100 %RH

Output resolution and units 0.1 %RH General Operating temperature -52 ... +60 °C (-60 ... +140 °F)

Storage temperature -60 ... +70 °C (-76 ... +158 °F)

Operating voltage 5 ... 32 VDC Typical power consumption 3 mA at 12 VDC (with preset value)

Heating voltage 5 ... 32 VDC (or AC, max. 30 VRMS) Serial data interface SDI-12, RS-232, RS-485, RS-422, USB interface Weight 650 g (1.43 lbs) Housing IP65 Housing with mounting kit IP66 Δ °C °C -0.7 0.7 0.6 0.5 0.4 0.3 0.2 0.1 -0.1 -0.2 -0.3 -0.4 -0.5 -0.6 0 -80 -60 -40 -20 0 20 40 60 80 Ref. B210417EN-A ©Vaisala 2009

This material is protected by copyright, all rights reserved by Vaisala and its partners. All rights reserved, and any logos and/or product names are trademarks of Vaisala and its partners. The information contained in this manual may not be reproduced, reprinted, distributed or stored in any form without the prior written permission of Vaisala. All specifications, including technical specifications, are subject to change without notice.

Output resolution and unit 0.1 °C, 0.1 °F Electromagnetic Compatibility Conforms to Electromagnetic Compatibility Standard EN61326-1,

Industrial environment Environmental IEC standard IEC 60945/61000-4-2 ... 61000-4-


Ntek AMGMini Amplifier Pink/White Noise Generator

 

01dB Cal31 is a class 1 acoustic calibrator for calibration and adjustment of any type of sound

 

Standard equipment

  • Wireless remote control
  • Antenna
  • Connector BNC/RCA
  • Soft cross bag shipping
Technical Features
  • Dimensions: 140 x 200 x 330mm
  • Weight: 3kg - with battery kit: 5kg
  • Frequency Response: 40 Hz - 10 KHz
  • Battery capacity: 1 hour full power
  • Noise Generator: White/Pink or via BNC/RCA
  • Connectors and other external sources
  • Meet specific customer needs
  • Channel number: 2 out
  • The maximum power of channel 4Ω: 350 W
  • SNR (signal-to-noise ratio): > 113 dBA
  • Total Harmonic Distortion THD+N: from 0.1 W < 0.05%
  • Full power (usually <0.01%)
  • Intermodulation Distortion DIM100: from 0.1 W < 0.02%
  • Full power (usually < 0.005%)
  • Power factor: cosφ> 0.85 - 4Ω at full power
  • Short Circuit Protection
  • DSP (Digital System Processor)
  • Building: 1702
  • Equalizer: All parametric filters per channel
  • Thermal Characteristics
  • Operating Range: 0° - 40°C / 32° - 104°F
  • Heat Protection
  • Legal Compliance
    • UNI EN ISO:
    • 3382, 354, 140, 16283.
    • Compliant with CE directives.

    Ntek TPM Pro floor hammering machine

     

    01dB Cal31 is a class 1 acoustic calibrator for calibration and adjustment of any type of sound

     

    Standard compliant

    • UNI EN ISO: 10140-3, 104-7, 16283-2,
    • ASTM: E492, E1007

    Specifications

    • Dimensions: 160 x 290 x 520mm
    • Weight: 11kg with battery kit
    • Fulcrum: 3 points retractable and height adjustable
    • Power supply: 100~240VAC, 50/60Hz
    • Power consumption: 220VA

    Battery

    • Rechargeable lithium battery
    • Duration: 3 hours
    • Battery Derating: <5% capacity loss every 900 discharge/charge cycles
    • Battery charging time: 2 hours

    Drop the hammer

    • Five falling hammers
    • Axial spacing: 100±3mm
    • Weight: 500±6 grams
    • Diameter: 30±0.2mm
    • Front Radius: 500mm
    • Curve: about 500mm
    • Tapping rate: 10 impacts per second,
    • The speed is controlled by the encoder feedback loop
    • Order: 1, 3, 5, 2, 4
    • Effective drop height: 40mm adjustable ±5mm

    Standard Accessories

    • Carrying bag
    • Lithium battery
    • Calibrator 73mm

    Germany CAE Bionic S Sound Imager

     

    See sounds and vibrations

    In the last few years, a new technology for the visualization of sound sources - the acoustic camera - has found impressive applications in industrial and environment-related fields due to its practicality and intuitive use. The acoustic design of a product is an important factor in product development. Ease of use and obvious effects give engineers a new meaning - "see the sound source with your eyes", which will greatly speed up product development, quality control and environmental measurement.

    Therefore, the developed acoustic camera "Noise Checker" is a set of powerful and flexible equipment, and the continuous improvement of "Noise Checker" provides you with the advantages of a precise, fast and intelligent technology; with this The system realizes the instant visibility of sound and vibration; in addition, even non-acoustic experts and professionals can easily use the software, the software provides powerful functions, and the results are easy for everyone to understand; therefore, Noise Inspector is an enhanced product quality, reducing development time and saving your resources an important product.

    It can be suitable for the user's application due to the flexible array design, the number of microphones and the advanced algorithm; it includes a variety of arrays in a single system, enabling beamforming, holography Smooth transmission between sound intensity measurement and sound intensity measurement is possible, so that the analysis object is wider and more diverse.

    Everything is designed to be presented with very high performance, and even better - at a lower cost!

    01dB has partnered with CAE Software and Systems, a German company, to provide customers with the best solution for acoustic cameras.

    Technical information

    Hardware

    • Array of innovations
    • 24 bit simultaneous sampling
    • Channels: 8 to 1000
    • High resolution results
    • High-resolution optical camera
    • Battery operated
    • Trigger and RPM channel
    • Equipment is lightweight
    • Small size
    • A flexible and mobile app

    Software

    • Quick instant panning
    • Postprocessing for high precision results
    • Powerful HD algorithms
    • AVI , WAV and export of results
    • Localized from 40Hz to 20kHz, depending on configuration
    • More than 40 dB of dynamic range
    • Acoustic Weighting Filter
    • With LabVIEW- and Matlab interface
    • Group or manual processing
    • Unique and realistic 3D beamforming
    • Intuitive and easy to use

    NOISE INSPECTOR'S SOLUTION

    Noise Inspector is designed for quick setup to save time and start measuring immediately, so we designed the system to be set up by only one person in about a minute; after setting up the hardware, just use the mouse Click for instant first sound pictures.

    4 important components of an acoustic camera:

    • Microphone Array: We provide the best and well-designed array.
    • Data collection (analog or digital): 24-bit resolution, designed for all applications, anti-aliasing filter and simultaneous sampling for each microphone.
    • Photography lens: Use high-definition digital cameras (USB and IP cameras)
    • Computing software: intuitive software, easy to use and powerful

    Application

    • Ambient Acoustics
    • Architectural Acoustics
    • Noise Leakage Detection NVH
    • Unusual sound
    • Transient noise sources
    • Stationary (static) noise